The **Angus TPS-80 Foam Top Pourer** is a fixed foam firefighting system component
designed to protect fixed-roof tanks used for storing flammable liquids. Manufactured
by Angus Fire, the Top Pourer Set combines foam generation, vapour sealing, and 
foam discharge in an integrated assembly. It is intended for industrial facilities
where a properly engineered fixed foam system is required for tank fire protection.

The TPS-80 is one of the sizes in the Angus Fire Top Pourer Set range. The exact
operating pressure, foam solution flow rate, installation arrangement, and pressure
compatibility must be confirmed against the selected model version and the system
design. Angus Fire offers TPS Mk4 and Mk5 versions for different tank pressure conditions,
so the version should be verified before ordering.

## Key Features of the Angus TPS-80 Foam Top Pourer

 * **Fixed-tank foam protection:** Designed for use in fixed-roof flammable liquid
   storage tank fire protection systems.
 * **Integrated assembly:** Combines foam generation, vapour sealing, and foam pouring.
 * **Foam deflector:** Guides discharged foam against the tank wall so it can flow
   gently onto the fuel surface.
 * **Controlled foam delivery:** Helps reduce splashing and unwanted mixing of foam
   with the stored liquid.
 * **Engineered flow performance:** The TPS-80 operating point must be selected 
   to match the required foam solution flow and inlet pressure.
 * **Installation options:** Angus TPS products offer installation arrangements 
   that can include standard or split-flange configurations, subject to model and
   order specification.
 * **Industrial application:** Suitable for consideration in engineered fire protection
   systems at tank farms, refineries, and petrochemical facilities.

Confirm the supplied model’s precise materials, dimensions, flange arrangement, 
approvals, and accessories with the current manufacturer documentation before specifying
these as guaranteed product features.

## Technical Specifications

  |  Specification |  Details |  
 |  Product name |  Angus TPS-80 Foam Top Pourer |  
 |  Manufacturer |  Angus Fire |  
 |  Product type |  Foam top pourer for fixed foam systems |  
 |  Model size |  TPS-80 |  
 |  Intended application |  Fixed-roof flammable liquid storage tanks |  
 |  Operating pressure |  Confirm exact model and design point |  
 |  Flow rate |  Confirm selected operating point |  
 |  Model version |  Mk4 or Mk5 — confirm before ordering |  
 |  Installation type |  Confirm required flange arrangement |  
 |  Dimensions and weight |  Confirm from the applicable datasheet |  
 |  Certifications and approvals |  Verify for the exact supplied configuration |

**Manufacturer reference:** The Angus Fire TPS Mk4 technical datasheet shows a TPS-
80 performance envelope spanning approximately 207–1,344 litres per minute across
its published 3–10 bar inlet-pressure range. These are envelope values, not a promise
that every unit operates at any flow in that range. The final flow rate depends 
on the selected orifice and operating pressure. Confirm that the Mk4 datasheet applies
to your product before publishing these figures as its specifications.

## Applications

The Angus TPS-80 may be specified as part of a professionally designed fixed foam
system for facilities such as:

 * Petroleum and fuel storage tank farms
 * Oil refineries
 * Petrochemical plants
 * Industrial flammable-liquid storage facilities
 * Other sites requiring fixed-roof tank foam protection

The final application suitability depends on the stored liquid, tank design, internal
pressure, foam concentrate, required application rate, and applicable fire protection
standards.

## How to Select the Correct TPS-80

Before purchasing, confirm the following details with your fire protection system
designer or supplier:

 1. **TPS version:** Identify whether the requirement is for Mk4 or Mk5. The versions
    have different tank-pressure suitability.
 2. **Operating conditions:** Confirm the required inlet pressure and design flow rate.
 3. **Tank details:** Provide the tank diameter, stored liquid, roof arrangement, and
    internal operating pressure.
 4. **Installation arrangement:** Check the required flange standard and whether a 
    standard or split-flange installation is needed.
 5. **Foam concentrate:** Confirm compatibility with the selected concentrate and the
    overall foam system design.
 6. **Documentation:** Request the current datasheet, installation details, and applicable
    approval information for the exact model.

The number and positioning of foam top pourers should be established through the
applicable design standards and a qualified fire protection engineering assessment.

## Why Buy from FASCO Pakistan?

FASCO supports customers looking for firefighting and industrial fire safety equipment
in Pakistan. If you are sourcing the Angus TPS-80 Foam Top Pourer for a new installation,
replacement, or project quotation, contact FASCO to confirm availability, the exact
model version, technical documentation, and the required installation configuration.

For an accurate quotation, provide the model designation, required flow and pressure,
flange details, and project requirements.

**Request a quotation from FASCO Pakistan for the Angus TPS-80 Foam Top Pourer and
confirm the correct configuration for your fixed foam firefighting system.**