# Edwards EST SIGA2-PS Intelligent Addressable Photoelectric Smoke Detector

- Link: https://fasco.pk/product/edwards-est-siga2-ps-smoke-detector/
- Published: 2026-11-19T17:10:12+05:00
- Author: Fasco Pakistan

## Edwards EST SIGA2-PS Intelligent Addressable Smoke Detector

The **Edwards EST SIGA2-PS Smoke Detector** is an intelligent addressable photoelectric
detector designed for the Edwards Signature Series fire alarm system. It uses an
optical sensing chamber and an integrated microprocessor to analyse smoke conditions
and communicate detector information to the fire alarm control panel.

This intelligent photoelectric detector combines electronic addressing, automatic
device mapping, environmental compensation and built-in diagnostics. Its advanced
sensing technology helps identify smoke conditions while filtering signal patterns
that are less typical of fire events.

### Key Features of Edwards EST SIGA2-PS

 * **Photoelectric Smoke Detection:** Uses optical sensing technology to detect 
   smoke particles entering the detector chamber.
 * **Intelligent Addressable Operation:** Communicates detector status and alarm
   information through a compatible Signature Series loop controller.
 * **Electronic Addressing:** Supports electronic device addressing without conventional
   address switches.
 * **Automatic Device Mapping:** Helps the compatible control panel identify connected
   devices and their arrangement.
 * **Environmental Compensation:** Automatically monitors environmental changes 
   to maintain detector performance.
 * **Selectable Sensitivity:** Provides five selectable alarm sensitivity settings
   and configurable pre-alarm levels.
 * **Self-Diagnostics:** Monitors detector condition and identifies dirty or defective
   sensing components.
 * **Dual-Colour LED Indicators:** Green and red LEDs provide visual indication 
   of detector status and alarm conditions.
 * **Replaceable Smoke Chamber:** Supports maintenance through a replaceable sensing
   chamber.
 * **Nuisance Alarm Reduction:** Digital signal processing helps distinguish fire-
   related smoke patterns from unwanted signals.

### Technical Specifications

  |  Specification |  Details |  
 |  Brand |  Edwards / EST |  
 |  Model |  SIGA2-PS |  
 |  Series |  Signature Series |  
 |  Detector Type |  Intelligent Addressable Photoelectric |  
 |  Detection Technology |  Optical / Photoelectric |  
 |  Operating Voltage |  15.20–19.95 VDC |  
 |  Normal Operating Current |  45 µA |  
 |  Alarm Current |  45 µA |  
 |  Standalone Alarm Current |  18 mA |  
 |  Operating Temperature |  0°C to 49°C |  
 |  Operating Humidity |  0–93% RH, non-condensing |  
 |  Air Velocity Range |  0–4,000 ft/min (0–20 m/s) |  
 |  Construction |  High-impact engineering polymer |  
 |  Colour |  White |  
 |  Address Requirement |  One device address |  
 |  System Compatibility |  Edwards EST Signature Loop Controller |

_Specifications are based on published SIGA2-PS product documentation. Confirm the
exact revision and product label before ordering._

### Compatible Detector Mounting Bases

The SIGA2-PS is a plug-in detector and requires a compatible mounting base. Manufacturer
documentation identifies the following base options:

 * **SIGA-SB:** Standard detector mounting base
 * **SIGA-SB4:** 4-inch detector mounting base with trim skirt
 * **SIGA-RB:** Relay detector mounting base
 * **SIGA-RB4:** 4-inch relay detector mounting base
 * **SIGA-IB:** Fault isolator detector mounting base
 * **SIGA-IB4:** 4-inch fault isolator detector mounting base
 * **SIGA-AB4G:** Audible sounder base

Select the appropriate base according to the installation design and the requirements
of the compatible fire alarm control panel.

### Applications

The Edwards EST SIGA2-PS Smoke Detector is intended for compatible fire detection
installations in:

 * Commercial buildings and office facilities
 * Industrial plants and manufacturing facilities
 * Warehouses and storage facilities
 * Hotels and institutional buildings
 * Marine and other specialised facilities where the system is approved for use

### System Compatibility and Installation

The SIGA2-PS is designed for use with the **Edwards EST Signature Series loop controller**.
It should not be treated as a conventional standalone smoke detector or assumed 
to work with unrelated fire alarm control panels.

Before installation, verify the detector model, loop-controller compatibility, mounting
base and system configuration. Installation, testing and maintenance should be carried
out by a qualified fire alarm technician in accordance with the manufacturer’s instructions
and applicable fire safety requirements.

Explore more detection products and accessories in our [**Fire Alarm Systems**](https://fasco.pk/product-category/fire-alarm-systems/)
category at FASCO.

### Why Choose Edwards EST SIGA2-PS?

The Edwards EST SIGA2-PS combines intelligent addressable communication with photoelectric
smoke detection and built-in diagnostic functions. Its electronic addressing, selectable
sensitivity, environmental compensation and replaceable smoke chamber make it a 
useful component for compatible Edwards Signature Series fire alarm installations.

**Brand:** Edwards / EST
 **Model:** SIGA2-PS **Product Type:** Intelligent Addressable
Photoelectric Smoke Detector **Series:** Signature Series