# TYCO / THORN MCP230 Outdoor Manual Call Point – EN 54-11

- Link: https://fasco.pk/product/tyco-mcp230-manual-call-point/
- Published: 2026-11-23T12:58:21+05:00
- Author: Fasco Pakistan

## Tyco / Thorn MCP230 Outdoor Manual Call Point

The **Tyco MCP230 Manual Call Point** is a conventional outdoor fire alarm activation
device developed for use in compatible fire detection and alarm systems. Manufactured
under the Thorn Security and Tyco brands, this model is designed to provide a manual
method of raising a fire alarm in outdoor and exposed installation environments.

The MCP230 features a break-glass operating mechanism, an integral LED indicator
and alert resistors. Its IP67-rated enclosure provides protection against dust and
water ingress, making it suitable for installations where ordinary indoor manual
call points may not provide adequate environmental protection.

### Key Features of Tyco MCP230 Manual Call Point

 * **Outdoor fire alarm activation:** Designed for manual alarm initiation in outdoor
   and exposed locations.
 * **IP67 protection:** Provides a high level of protection against dust and water
   ingress.
 * **Break-glass operation:** Allows users to activate the fire alarm manually.
 * **Integral LED indicator:** Provides visual indication of call point activation.
 * **Alert resistors:** Includes alert-level resistors for compatible conventional
   fire alarm circuits.
 * **Anti-tamper design:** Incorporates a secure enclosure design to help prevent
   unauthorised interference.
 * **EN 54-11 Type A:** Identified for manual fire alarm activation in accordance
   with the relevant European standard.

### Technical Specifications

  |  Specification |  Details |  
 |  Manufacturer |  Tyco / Thorn Security |  
 |  Model |  MCP230 |  
 |  Product type |  Conventional outdoor manual call point |  
 |  Thorn order code |  514.001.110.T |  
 |  Tyco order code |  514.001.110.Y |  
 |  Activation method |  Break-glass |  
 |  Operating category |  Type A |  
 |  Standard |  EN 54-11 |  
 |  Protection rating |  IP67 |  
 |  Alarm indication |  Integral LED |  
 |  Circuit configuration |  Alert resistors |  
 |  Installation |  Outdoor / surface mounting |  
 |  Country of origin |  UK, subject to product-label confirmation |

### Applications

The Tyco / Thorn MCP230 is suitable for compatible fire alarm installations requiring
outdoor manual alarm activation. Typical application environments include:

 * Industrial and manufacturing facilities
 * Outdoor building areas
 * Warehouses and storage facilities
 * Commercial premises
 * Marine and exposed installation areas
 * External access routes and building perimeters

### Installation and Wiring

The MCP230 is intended for connection to compatible conventional fire alarm circuits.
Its alert resistor configuration must match the control panel and system wiring 
requirements.

For wiring information, refer to the supplied **D 902 wiring reference** and the
manufacturer’s installation documentation. Confirm the correct terminal connections
and circuit resistor arrangement before installation.

For more fire detection equipment, explore the [FASCO Fire Alarm Systems collection](https://fasco.pk/product-category/fire-alarm-systems/).

**Important:** The MCP230 is an outdoor manual call point, not a detector. Verify
the exact Tyco or Thorn order-code suffix and the existing fire alarm panel’s compatibility
before purchasing or replacing the unit.