ZETA Premier Elite 2-Zone Conventional Fire Alarm Control Panel
Wholesale pricing, tiered volume discounts, and GST invoice terms provided based on your required quantity and delivery location across Pakistan.
Product Technical Overview
ZETA Premier Elite 2-Zone Conventional Fire Alarm Control Panel
The ZETA Premier Elite 2-Zone Fire Alarm Panel is a conventional fire alarm control unit developed by ZETA by GLT for smaller fire detection installations. It monitors two independent detector zones and provides audible and visual indications when a fire alarm or system fault occurs.
Designed for straightforward installation and operation, the Premier Elite panel includes two conventional sounder circuits, an alarm relay and a battery-backed 24V DC power system. Its control interface provides essential functions such as sounder operation, alarm silence, system reset and LED testing.
Key Features of ZETA Premier Elite 2-Zone
- Two Detection Zones: Monitors two independent conventional fire detection circuits.
- Two Sounder Circuits: Provides separate outputs for compatible conventional fire alarm sounders.
- 24V DC Battery Backup: Uses two 12V sealed lead-acid batteries to provide backup power.
- Integrated Power Supply: Includes a built-in battery charger and power supply arrangement.
- Fire Relay Output: Provides a relay output for compatible external fire signalling equipment.
- Zone Fault Monitoring: Indicates faults associated with detector circuits and connected devices.
- Sounder Fault Monitoring: Monitors the sounder circuits and indicates wiring faults.
- LED Status Indication: Provides visual indications for power, general fire, zone fire, general fault and supply fault conditions.
- Simple Operating Controls: Includes Start/Stop, Silence, Reset and LED Test buttons.
- Key-Switch Operation: Helps restrict access to operational controls to authorised personnel.
- Straightforward Installation: Designed for conventional detectors, manual call points and compatible sounder devices.
Technical Specifications
| Specification | Details |
|---|---|
| Brand | ZETA by GLT |
| Series | Premier Elite |
| Model | 2-Zone |
| Product Type | Conventional Fire Alarm Control Panel |
| Number of Detection Zones | 2 |
| Maximum Devices per Zone | 20 |
| Sounder Circuits | 2 |
| Sounder Output | 2 × 400mA at 24V DC nominal |
| Mains Supply | 230V AC ±10%, 50/60Hz |
| Battery Supply | 24V DC |
| Backup Batteries | 2 × 12V sealed lead-acid batteries |
| Battery Charger | 1A |
| Auxiliary Fire Output | 1 SELV relay, maximum 1A |
| Zone End-of-Line Device | 10kΩ resistor |
| Sounder End-of-Line Device | 10kΩ resistor |
| Enclosure Dimensions | 355 × 275 × 100mm |
| Mounting | Wall-mounted |
Applications
The ZETA Premier Elite 2-Zone is suitable for smaller conventional fire detection installations, including:
- Small commercial buildings
- Offices and business premises
- Retail shops and small stores
- Residential and apartment buildings
- Workshops and small industrial facilities
- Small institutional and educational premises
Compatible Detection Devices and Accessories
The panel is designed for compatible conventional fire detection equipment, including:
- Conventional optical smoke detectors
- Conventional heat detectors
- Manual call points
- Conventional fire alarm sounders
- Compatible fire alarm interface and signalling equipment
The panel uses conventional zone wiring with a 10kΩ end-of-line resistor. Detector bases with continuity diodes may not be compatible with this particular panel configuration; check the manufacturer's wiring instructions before selecting detector bases.
Operation and Control Functions
The Premier Elite provides straightforward controls for everyday fire alarm operation and maintenance.
- Start/Stop Sounders: Allows authorised users to start or stop connected fire alarm sounders.
- Silence Fault Tone: Silences the internal panel buzzer during a fault or alarm condition.
- System Reset: Returns the panel to normal after the alarm condition has been cleared.
- LED Test: Checks the operation of the panel's visual indicators.
- Zone Monitoring: Provides separate fire and fault indications for each detection zone.
Installation and Compatibility
The ZETA Premier Elite 2-Zone is a conventional fire alarm control panel. Connected detectors and manual call points operate through zone circuits rather than individual electronic addresses.
Before installation, verify detector compatibility, zone loading, sounder current consumption, cable requirements and battery capacity. All wiring and end-of-line components must follow the manufacturer's installation manual.
Explore additional fire detection equipment and accessories in our Fire Alarm Systems category.
Why Choose the ZETA Premier Elite 2-Zone?
The ZETA Premier Elite 2-Zone combines essential fire detection monitoring, sounder control and fault indication in a straightforward conventional fire alarm panel. Its two detection zones, independent sounder circuits and battery-backed power supply make it a practical option for smaller installations requiring conventional fire alarm protection.
Brand: ZETA by GLT
Series: Premier Elite
Model: 2-Zone
Product Type: Conventional Fire Alarm Control Panel
Detection Zones: 2
Key Industrial Features
- Heavy-Duty Construction: Built for severe industrial environments, extreme temperature resistance, and high-frequency operational duty.
- Standardized Ergonomics: Designed for prolonged wearing and user comfort without sacrificing required safety margins.
- Certified Reliability: Full batch inspection traceability guaranteeing compliance with required safety standards.
- Corporate Supply Support: Bulk packaging, user safety training documentation, and manufacturer test certificates available on request.
Recommended Applications & Industries
Regulatory Standards & Certifications
All products distributed by FASCO Pakistan are subject to stringent quality inspection and comply with one or more of the following international and national safety authorities:
Technical Datasheets & Compliance Certificates
To request official manufacturer datasheets, mill test certificates, or tender compliance documentation, please contact our engineering desk:
Nationwide Delivery & Corporate Logistics
- Dispatch Time: In-stock orders are dispatched within 24 to 48 hours from our central distribution hubs in Karachi and Lahore.
- Major Cities Covered: Karachi, Lahore, Islamabad, Rawalpindi, Faisalabad, Multan, Gujranwala, Peshawar, Quetta, Sialkot, Hyderabad and all surrounding industrial zones.
- Logistics Partners: Trax, TCS, Leopard Courier, Daewoo Fastex, and dedicated freight carriage for heavy bulk shipments.
- Payment Options: Cash on Delivery (COD) for eligible parcels, Advance Online Bank Transfer (IBFT), and Corporate Purchase Orders (PO) with credit terms for approved corporate accounts.